Dome Cameras DWG Block for AutoCAD

Bathroom, Plumbing Pipe Fittings

Hotel, Restaurants Recreation

Water Sewage Electricity Infrastructure

Electronic Components Devices

Heavy Equipment Construction Sites

Patterns, Textures Backgrounds

Construction Details Systems

Mechanical, Electrical Plumbing (MEP)

Design installation of CCTV cameras dome with anti-theft device

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Production exploration division, Petroleum s. to., Construction engineer, Original broadcast, Issuance for tender, Emission for construction, Format, do not., review:, by:, Lp, do not., date:, by:, do not., review:, date:, Plane no:, Plane no:, Contract no, designed, Drawn, approved, date:, reviewed, contractor, management, Outdoor electrical installations, Seat second part building engineering, Plan no., Cilium polanco, Luis pineda, Elio montilla, reviewed:, designed:, approved:, scale:, Luis castillo, Harry branchi, Operator cad:, date:, Project no., content:, Fac., Rev., File not., No plan, File no .:, source, of power, Ac conection, Switch, Limit, Low voltage, Battery, Conection, Battery, Conection, Bench type, concrete, Red concrete, P.v.c., existing, detail, With equipment, compacted fill, percussion, Level of, ground, Little detail, strip, metal, post, Cm concertina, Conduit arg, Reducer arg, concrete, Poor concrete, Camera mount detail, Hg curve, antenna, Iron pipe, Black diam, Welded to the post, Nema box, Dry transformer, Nema box, Kva, Dimensions according to specification, Spectra iii camera, fixation System, Protection system, Chinese cap type, Tanquilla type, Pvc bench, File no .:, No plan, do not., review:, Emission for construction, Issuance for tender, Original broadcast, Format, do not., by:, date:, do not., review:, by:, Plane no:, date:, Plane no:, contractor, reviewed, date:, approved, Drawn, designed, Contract no, Installation of cctv systems of the operational area guafita, General details civil electromechanical works, Operator cad:, designed:, reviewed:, content:, Project no., date:, scale:, approved:, File not., Rev., Plan no., Little detail, Profile in the form of, Concrete cover with frame, asphalt, kind, Similar simalla, welded Mesh, Esc., cut, Tanquilla type, ground, Level of, percussion, compacted fill, With equipment, P.v.c., concrete, Bench type, top view, Concertina support detail, lighting rod, tip, Franklin, Connector, barracuda, two eyes, driver

Raw text data extracted from CAD file:

\A1;47.00 \A1;6.40 \A1;6.40 \A1;7.20 \A1;7.00 \A1;7.20 \A1;6.40 \A1;6.40 \A1;20.00 \A1;6.00 \A1;8.00 \A1;6.00 1 2 3 4 5 6 7 8 A B C D 5 5 5 5 5 5 5 5 5 5 5 5 Divisin Exploracin y Produccin PETRLEO S. A. INGENIERIA Y CONSTRUCCION 00 EMISION ORIGINAL 01 EMISION PARA LICITACION 02 EMISION PARA CONSTRUCCION FORMATO E (30×42) No. 1 REVISION: P L A N O S D E R E F E R E N C I A: POR: JULIO/01 L.P No. FECHA: POR: No. REVISION: 2 FECHA: PLANO No: T I T U L O: 3 PLANO No: T I T U L O: CONTRATO Nº DISEÑADO DIBUJADO APROBADO FECHA: REVISADO CONTRATISTA PDVSA, 4 GERENCIA INSTALACIONES ELECTRICAS EXTERIORES SEDE SEGUNDA PARTE EDIFICIO 6 INGENIERIA PDVSA-SUR PLANO No. CILIO POLANCO JULIO/01 LUIS PINEDA ELIO MONTILLA REVISADO: ~ DISENADO: APROBADO: ESCALA: 1:50 LUIS CASTILLO HARRY BRANCHI OPERADOR CAD: FECHA: PROYECTO No. CONTENIDO: PLANOS/BARINAS NORTE/OFICINAS FAC. 5 REV. ARCHIVO No. C B A PLANO No.: ARCHIVO No.: – – 1 2 3 4 5 C B A -06 FUENTE DE PODER 12VDC 5A AC CONECTION SWITCH LIMIT LOW VOLTAJE AC AC BATTERY CONECTION DC + – BATTERY CONECTION T A – + B 76050526 -13 1 \A1;.40 \A1;.15 \A1;.05 \A1;.075 \A1;.75 \A1;.05 \A1;.075 \A1;.20 \A1;.075 \A1;.075 \A1;.05 -126162.8995086291 -126162.8995086291 -126162.8995086291 -126162.8995086291 -126162.8995086291 -76459. BANCADA TIPO B2 s/e -76459. -126162.8995086291 -126162.8995086291 -126162.8995086291 -126162.8995086291 CONCRETO 80 Kg/Cm2 CONCRETO ROJO P.V.C. d 2 EXISTENTE DETALLE s/e 3 CON EQUIPO A RELLENO COMPACTADO PERCUSION NIVEL DEL TERRENO DETALLE TANQUILLA \A1;2.00 \A1;0.20 \A1;5,40 mt \A1;11,00 mt \A1;0,20 \A1;4,00 mt \A1;0,40 \A1;0,60 \A1;0.40 \A1;1.40 mt \A1;1.20 mt \A1;0.05 \A1;0.05 \A1;0.05 \A1;0.075 \A1;0.075 \A1;0.70 \A1;0.70 \A1;0.05 \A1;0.60 \A1;0.05 \A1;0.50 \A1;0.10 \A1;0.10 \A1;0.075 \A1;0.05 \A1;0.075 \A1;0.45 \A1;0.45 \A1;0.30 \A1;0.075 \A1;0.05 \A1;0.075 \A1;0.10 \A1;1.05 \A1;0.65 \A1;45.19 \A1;10.73 \A1;17.23 \A1;17.23 \A1;22.59 \A1;22.59 \A1;22.86 5,40 mt 0.20 2.00 FLEJE METALICO 1/2 POSTE CONCERTINA DE d 45 cm CONDUIT ARG d 3/4 REDUCTOR ARG d2 A 3/4 CONCRETO 210 kg/cm2 CONCRETO POBRE e=0.05 DETALLE DEL MONTAJE DE CAMARA 11,00 mt 0,20 CURVA DE 2 HG 4,00 mt 0,40 0,60 0.40 1.40 mt 1.20 mt ANTENA TUBERIA DE HIERRO NEGRO DIAM = 2 SOLDADA AL POSTE CAJA NEMA 4X 60 x 60 x 40 cm TRANSFORMADOR SECO CAJA NEMA 4X 1,2 KVA 480 / 240-120 DIMENSIONES SEGUN PLIEGO CAMARA SPECTRA III SISTEMA DE FIJACION SISTEMA DE PROTECCION TIPO GORRO CHINO d2 TANQUILLA TIPO E-2 BANCADA B2C2 PVC ARCHIVO No.: PLANO No.: 1 – – 2 3 4 5 C B A No. REVISION: 1 02 EMISION PARA CONSTRUCCION 01 EMISION PARA LICITACION 00 EMISION ORIGINAL FORMATO E (30×42) No. POR: FECHA: No. 2 REVISION: POR: P L A N O S D E R E F E R E N C I A: PLANO No: FECHA: PLANO No: T I T U L O: T I T U L O: 3 CONTRATISTA REVISADO FECHA: APROBADO DIBUJADO DISEÑADO CONTRATO Nº INSTALACION DE LOS SISTEMAS CCTV DEL AREA OPERACIONAL GUAFITA DETALLES GENERALES OBRAS ELECTROMECANICAS Y CIVILES OPERADOR CAD: DISENADO: REVISADO: 4 CONTENIDO: PROYECTO No. FECHA: S/E ESCALA: APROBADO: ~ — MARZO/06 — ARCHIVO No. REV. 5 PLANO No. —— 1 0.65 1.05 0.10 0.075 0.05 0.075 0.30 0.45 DETALLE TANQUILLA 2 x d2 2 x d2 0.45 0.075 0.05 0.075 d2 d2 PERFIL EN FORMA DE L TAPA DE CONCRETO CON MARCO DE 1 x 1 ASFALTO TIPO R-1.31 SIMALLA O SIMILAR MALLA ELECTROSOLDADA ESC. S/E CORTE B-B TANQUILLA TIPO TD-2 0.10 0.10 0.50 0.05 0.60 0.05 0.70 0.70 0.075 0.075 0.05 0.05 0.05 TERRENO NIVEL DEL PERCUSION RELLENO COMPACTADO CON EQUIPO A P.V.C. d 2 CONCRETO 210 Kg/Cm2 BANCADA TIPO B2 5 5 5 5 5 5 5 VISTA SUPERIOR DETALLE SOPORTE CONCERTINA DETALLE SOPORTE CONCERTINA PARARRAYOS PUNTA FRANKLIN CONECTOR BARRACUDA DOS OJOS N 2/0 CONDUCTOR AWG-THW

Mechanical, Electrical & Plumbing (MEP)

autocad,block,cameras,cctv,Design,device,dome,DWG,einrichtungen,facilities,gas,gesundheit,installation,lapprovisionnement en eau,la sant,le gaz,machine room,maquinas,maschinenrauminstallations,provision,wasser bestimmung,water

DWG_BlocksView All DownloadsPost navigationPreviousElectrical Details DWG Detail for AutoCADNextDepartment Electrical Project DWG Full Project for AutoCADLeave a ReplyCancel reply

Your email address will not be published.Required fields are marked*

Save my name, email, and website in this browser for the next time I comment.

Mechanical, Electrical & Plumbing (MEP)

autocad,block,cameras,cctv,Design,device,dome,DWG,einrichtungen,facilities,gas,gesundheit,installation,lapprovisionnement en eau,la sant,le gaz,machine room,maquinas,maschinenrauminstallations,provision,wasser bestimmung,water